A B C O N V / F L C O N V / I R C O N V
Converts a spectrum into AB magnitudes (ABCONV) or f-lambda
units (ergs/sec/cm**2/A) (FLCONV), or W/m**2/um (IRCONV).
The original units of the
data may be Janskys, milli-Janskys, or micro-Janskys. Other
possibilities may be added later.
Command parameters -
SPECTRUM The name of the structure containing the spectrum.
currently used for the spectrum. For FLCONV
an x-axis data structure giving the wavelengths of the
data elements is also required.
OUTPUT The name of the result of the operation. This can
be the same as for SPECTRUM. If not, a new structure
is created, with everything but the data a direct
copy of the input.
Command keywords - None
User variables used - None
KS / CIT 18th May 1984
FIGARO A general data reduction system