IPCS2STOKES
reduces data obtained with the AAO
Pockels cell spectropolarimeter with the IPCS
as
detector. The data is read in the form of Figaro files each containing a pair of A and B state frames
forming a single observation. Within each A and B frame there are four spectra corresponding to the O
and E rays for each of two apertures (A and B). These spectra are combined to derive a Stokes
parameter spectrum in TSP
format.
1 | FIGARO | Char | The input Figaro data file. |
ASTART | Integer | The Start column for the A aperture data. |
|
BSTART | Integer | The Start column for the B aperture data. |
|
OESEP | Integer | The distance in columns from the start of the O spectrum to the start of the E spectrum. |
|
WIDTH | Integer | The number of columns to include in each extracted spectrum. |
|
APERTURE | Char | The aperture containing the star (A or B). |
|
STOKESPAR | Char | The Stokes parameter (Q,U,V). |
|
OUTPUT | TSP , 1D | The Output dataset. |